Amoxicillin Quantitative Rapid Test Kit
Fluorescence Immunoassay
This competitive quantum dot fluorescence immunochromatographic assay quantitatively screens amoxicillin residues in livestock and poultry tissues across a detection range of 20–200 µg/kg. After sample addition, the XY-1200 automatically incubates and reads the test card, delivering results in 12 minutes.
Performance data
Specifications
| Catalog No. | XVFA067RA05 |
|---|---|
| Product Name | Amoxicillin Quantitative Rapid Test Kit |
| Target Analyte | Amoxicillin residues |
| Detection Technology | Competitive quantum dot fluorescence immunochromatography |
| Result Type | Quantitative, automatically read by the XY-1200 |
| Applicable Matrix | Livestock and poultry tissues |
| Sample Preparation | Direct Extraction (followed by centrifugation and dilution) |
| Sample Volume | 150 µL |
| Time to Result | 12 min from sample addition to result (automatic incubation and reading) |
| Pack Size | 40 tests |
| Storage & Shelf Life | |
| Compatible Analyzer | XY-1200 Integrated Incubation and Fluorescence Reader |
| Relative Cross-Reactivity | — |
Kit Components
1. Detection Kit Components (40 Tests)
| Component | Quantity |
|---|---|
| Microwells | 8 wells × 5 strips = 40 wells |
| Test Strips | 40 strips |
| USB Drive | 1 pc |
| Instruction Manual | 1 copy |
2. Sample Preparation Kit I Components (Available Separately)
| Component | Quantity |
|---|---|
| Sample Extraction Solution A | 4 bottles × 50 mL |
| Dilution Buffer 05 | 2 bottles × 50 mL |
| Instruction Manual | 1 copy |
Multiple Assays from One Primary Extract
All assays listed below use the same primary extraction: 1.00 g of homogenized sample with 4 mL of Sample Extraction Solution A, followed by shaking for 3‑5 minutes and centrifugation at 4,000 rpm for 5 minutes. Aliquots of the same extract are then diluted according to the target assay.
Compatible Assays Using the Same Sample Preparation
| Compatible Assay | Sample Supernatant | Dilution Buffer 05 | Applicable Matrix |
|---|---|---|---|
| Sulfonamides | 300 µL | 1,200 µL | Livestock and poultry tissues |
| Quinolones | 300 µL | 1,200 µL | Livestock and poultry tissues |
| Tetracyclines I | 300 µL | 1,200 µL | Livestock and poultry tissues |
| Tetracyclines II | 300 µL | 1,200 µL | Livestock and poultry tissues |
| Tilmicosin | 300 µL | 1,200 µL | Livestock and poultry tissues |
| Tylosin | 300 µL | 1,200 µL | Livestock and poultry tissues |
| Cyromazine | 300 µL | 1,200 µL | Livestock and poultry tissues |
| Erythromycin | 300 µL | 1,200 µL | Livestock and poultry tissues |
| Enrofloxacin + Ciprofloxacin | 300 µL | 1,200 µL | Livestock and poultry tissues |
| Thiamphenicol | 300 µL | 1,200 µL | Livestock and poultry tissues |
| Trimethoprim | 20 µL | 1,000 µL | Livestock and poultry tissues |
| Florfenicol | 20 µL | 1,000 µL | Livestock and poultry tissues |
| Lincomycin | 20 µL | 1,000 µL | Livestock and poultry tissues |
| Spiramycin | 20 µL | 1,000 µL | Livestock and poultry tissues |
| Spectinomycin | 20 µL | 1,000 µL | Livestock and poultry tissues |
| Nicarbazin Metabolite | 200 µL | 200 µL | Livestock and poultry tissues |
| Pefloxacin | 200 µL | 200 µL | Livestock and poultry tissues |
Required Instruments and Materials (Not Provided)
XY‑1200 Integrated Incubation and Fluorescence Reader
Electronic balance
Sample homogenizer
Shaker
Vortex mixer
Centrifuge
10 mL and 2 mL centrifuge tubes
20‑200 µL and 100‑1,000 µL pipettes with compatible tips
Sample Preparation Kit I for the validated livestock and poultry tissue protocol (available separately)
Note: For compatible instruments and consumables, please contact the manufacturer.
Why Our Solution Stands Out
Designed for rapid quantitative screening of veterinary drug residues in foods of animal origin, Xinyu Bio's fluorescence immunoassay solution combines matched test kits, standardized sample preparation and automated instrument reading for routine quality control across the farm-to-table supply chain.
Automated, High-Throughput Testing
After sample addition, the XY-1200 automatically completes incubation and fluorescence reading. Up to 12 samples can be processed per run, with results available in 12 minutes, reducing hands-on time for routine batch screening.
Reliable Quantitative Performance
Quantum dot fluorescence immunochromatography combines sensitive detection with instrument-based signal analysis for objective quantitative results. Validated matrices typically achieve 80-120% recovery, supporting consistent routine screening.
Streamlined Workflows, Traceable Data
Matched sample preparation kits standardize extraction, dilution and cleanup across the product portfolio. Within compatible assay groups, one sample extract can support multiple residue tests, while integrated data management enables result storage, review and traceability.